STRC provides expert mechanical & electro-mechanical calibration services to a wide range of industries from aerospace to pharmaceutical & many more.
The breadth of our capabilities allows us to respond to the diverse electro & mechanical calibration services needs of our customers, within the best possible turnaround time.
We use calibration standards, traceable to national and international standards, to ensure the highest measurement confidence to our customers.
Scope of Accreditation:
MASS
Weight$ ( Conventional Mass) |
1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 50 kg |
0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.02 mg 0.03 mg 0.03 mg 0.04 mg 0.04 mg 0.02 mg 0.03 mg 0.02 g 0.02 g 0.02 g 0.2 g 0.2 g 0.5 g 4.3 g |
Using Standard Weights of E2 Class, F1 Class and Weighing Balance Substitution method as per OIML R-111-1: 2004 |
Weighing Balance♣ (Electronic) |
1 mg to 500 mg 500 mg to 50 g 50 g to 200 g 200 g to 2 kg 2 kg to 20 kg |
0.10 mg 0.15 mg 0.4 mg 28 mg 0.4 g |
Using F1 & M1 Class Weights Method as per OIML R-76-1: 2006 |
1 mg to 2000 g Readability: d= 0.01 mg & 0.1 mg |
0.1 mg | Using Weight Class E2 Procedure based on OIML R-76-1: 2006 | |
200 g to 1 kg Readability: d=1 mg 1 kg to 2 kg Readability: d=0.01 g |
3.0 mg 20 mg |
Using Std. Weight Class F1 Upto 50 kg (20 kg, 20kg, 10 kg), M1 | |
2 kg to 20 kg Readability: d=0.1 g 20 kg to 100 kg Readability: d=10 g |
0.30 mg 0.013 mg |
VOLUME
Volume$ (Laboratory Glassware) |
1 ml 2 ml 5 ml 10 ml 20 ml 25 ml 50 ml 100 ml 200 ml 250 ml 500 ml 1000 ml 2000 ml |
0.0001 ml 0.0003 ml 0.0003 ml 0.0004 ml 0.0004 ml 0.0004 ml 0.001 ml 0.001 ml 0.003 ml 0.002 ml 0.004ml 0.012 ml 0.015 ml |
Using Weight & Precision balance by Gravimetric Method as per IS/ ISO 4787:2010 |
Volume$ (Micropipette) |
10 µl 20 µl 50 µl 100 µl 200 µl 500 µl 1000 µl |
0.06 µl 0.08 µl 0.06 µl 0.06 µl 0.06 µl 0.06 µl 0.06 µl |
Using Precision Balance (Upto 50 g, 0.01 mg) by Volumetric Method based on ISO 8655-6: 2002 |
ACCELERATION & SPEED
RPM Contact Type ♣ | 20 rpm to 3000 rpm | ± 6 % rdg | Using Standard Tachometer |
RPM Non-Contact Type ♣ | 20 rpm to 20000 rpm | ± 6 % rdg |
ACOUSTICS
Sound Level Meter♯ | 94dB , 114dB | ±1.2 dB | Using Sound Level |
PRESSURE & VACUUM
Hydraulic Pressure- Dial Pressure Gauges, Digital Pressure Gauge, Pressure Indicator System, Pressure Transmitters ♯ |
2.5 kg/cm² to 50 kg/cm²>50 kg/cm² to 600 kg/cm² | 0.20 kg/cm² 0.30 kg/cm² | By Comparison method: Using Digital Pressure Gauge ( DKD-R6.1) |
Pneumatic PressurE ♯ (Megnehelic Gauge) | Upto 2940 Pa | 23.52 Pa | Using Digital Pressure Gauge |
Vacuum – Negative Pressure ♯ | -600 mmHg to 0 mmHg | 5.9 mm Hg | Using Digital Pressure Gauge |
FORCE
Verification of Static Uniaxial Testing Machines ♯ Tension & Compression Compression : |
2 kN to 200 kN 200 kN to 2000 kN |
0.52 % ** 0.54 % ** |
Using Load Cell Using Proving Ring as per IS: 1828 Part-1 2005 |